Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 968
Filtrar
1.
BMC Ophthalmol ; 24(1): 175, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627709

RESUMO

PURPOSE: The purpose of this study was to compare the preoperative anxiety, aqueous humor monocyte chemoattractant protein-1 (MCP-1) concentration, intraoperative pain, and degree of cooperation of the first eye implantable collamer lens (ICL) surgery with the second eye surgery, of the 1-day interval group with the 1-week interval group, and to investigate the possible causes of these differences, as well as to determine the appropriate interval between bilateral eye ICL surgeries. METHOD: The study was a prospective observational study. A total of 120 patients who underwent bilateral ICL surgery at the Department of Ophthalmology, West China Fourth Hospital, Sichuan University, from July to September 2023, were enrolled. The patients were divided into a 1-day interval group and a 1-week interval group. The ICL surgery was performed on both eyes according to the schedule. Anxiety levels, aqueous humor MCP1, cooperativeness, surgical time, pain and satisfaction, and patients' estimations of the time spent in the operation were recorded for each eye. The patients were instructed to recall the intraoperative pain of the first eye surgery after the operation of the second eye. Statistical analyses (two independent samples t-test,two paired samples t-test, the rank-sum test, the chi-square test, non-parametric test with multiple independent samples) were performed to compare the differences between each score in both eyes and two groups. Furthermore, we examined the relationship between pain levels and the reproductive history of the patients. RESULTS: In the 1-day interval group, male/female is 22/52, average age is 25.24±5.00. In the 1-week interval group, male/female is 17/29, average age is 25.39±5.57. There was no statistically significant difference between the two groups. In both groups, patients were less nervous, had significantly more pain, had less surgical satisfaction, had a longer estimated operative time, and had elevated preoperative MCP1 during the second eye operation. In the second eye surgery, the patient's cooperation worsened, but it did not lead to an increase in surgical time. A significant proportion of patients, particularly in the 1-week interval group, recalled experiencing reduced pain during the first eye surgery. The 1-week interval group had a higher difference in all indicators between the bilateral surgeries. In the second eye surgery, patients in the 1-week interval group experienced more severe pain, less cooperation, longer estimated operation duration, and a greater MCP1 than those in the 1-day interval group. CONCLUSION: Patients undergoing second eye ICL surgery had decreased nervousness, increased pain, decreased cooperation, and satisfaction, and increased MCP1 compared to the first eye surgery. It is recommended that an interval of about one week should be avoided between bilateral surgeries when developing a surgical schedule to improve patients' cooperation, satisfaction, and comfort.


Assuntos
Lentes Intraoculares , Miopia , Lentes Intraoculares Fácicas , Humanos , Masculino , Feminino , Implante de Lente Intraocular , Miopia/cirurgia , Olho , Dor/cirurgia
2.
J Refract Surg ; 40(4): e199-e207, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593258

RESUMO

PURPOSE: To investigate the efficacy of incorporating Generative Adversarial Network (GAN) and synthetic images in enhancing the performance of a convolutional neural network (CNN) for automated estimation of Implantable Collamer Lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT). METHODS: This study was a retrospective evaluation using synthetic data and real patient images in a deep learning framework. Synthetic ICL AS-OCT scans were generated using GANs and a secondary image editing algorithm, creating approximately 100,000 synthetic images. These were used alongside real patient scans to train a CNN for estimating ICL vault distance. The model's performance was evaluated using statistical metrics such as mean absolute percentage error (MAPE), mean absolute error (MAE), root mean squared error (RMSE), and coefficient of determination (R2) for the estimation of ICL vault distance. RESULTS: The study analyzed 4,557 AS-OCT B-scans from 138 eyes of 103 patients for training. An independent, retrospectively collected dataset of 2,454 AS-OCT images from 88 eyes of 56 patients, used prospectively for evaluation, served as the test set. When trained solely on real images, the CNN achieved a MAPE of 15.31%, MAE of 44.68 µm, and RMSE of 63.3 µm. However, with the inclusion of GAN-generated and algorithmically edited synthetic images, the performance significantly improved, achieving a MAPE of 8.09%, MAE of 24.83 µm, and RMSE of 32.26 µm. The R2 value was +0.98, indicating a strong positive correlation between actual and predicted ICL vault distances (P < .01). No statistically significant difference was observed between measured and predicted vault values (P = .58). CONCLUSIONS: The integration of GAN-generated and edited synthetic images substantially enhanced ICL vault estimation, demonstrating the efficacy of GANs and synthetic data in enhancing OCT image analysis accuracy. This model not only shows potential for assisting postoperative ICL evaluations, but also for improving OCT automation when data paucity is an issue. [J Refract Surg. 2024;40(4):e199-e207.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Tomografia de Coerência Óptica/métodos , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Miopia/cirurgia
4.
J Cataract Refract Surg ; 50(5): 448-452, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38651696

RESUMO

PURPOSE: To develop an accurate deep learning model to predict postoperative vault of phakic implantable collamer lenses (ICLs). SETTING: Parkhurst NuVision LASIK Eye Surgery, San Antonio, Texas. DESIGN: Retrospective machine learning study. METHODS: 437 eyes of 221 consecutive patients who underwent ICL implantation were included. A neural network was trained on preoperative very high-frequency digital ultrasound images, patient demographics, and postoperative vault. RESULTS: 3059 images from 437 eyes of 221 patients were used to train the algorithm on individual ICL sizes. The 13.7 mm size was excluded because of insufficient data. A mean absolute error of 66.3 µm, 103 µm, and 91.8 µm were achieved with 100%, 99.0%, and 96.6% of predictions within 500 µm for the 12.1 mm, 12.6 mm, and 13.2 mm sizes, respectively. CONCLUSIONS: This deep learning model achieved a high level of accuracy of predicting postoperative ICL vault with the overwhelming majority of predictions successfully within a clinically acceptable margin of vault.


Assuntos
Aprendizado Profundo , Implante de Lente Intraocular , Miopia , Lentes Intraoculares Fácicas , Humanos , Estudos Retrospectivos , Miopia/cirurgia , Adulto , Feminino , Masculino , Período Pós-Operatório , Inteligência Artificial , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Adulto Jovem , Redes Neurais de Computação
5.
Int Ophthalmol ; 44(1): 141, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38492122

RESUMO

PURPOSE: Phakic intraocular lenses treat higher degrees of myopia not possible previously with conventional refractive surgery. The aim of this study is to report the incidence and risk factors of retinal complications after posterior chamber PIOL implantation and assess the differences in biometric parameters between patients who developed such complications versus those who did not. METHODS: This retrospective study recruited 514 patients who underwent ICL implantation to correct myopia at a tertiary eye hospital center in the Eastern province of Saudi Arabia. Follow up period was at least one year. Medical records of the patients were reviewed to obtain the required data. Associations between respondents' characteristics and retinal complications were evaluated using the Chi-squared test. RESULTS: The mean (SD) age was 27.7 (± 6.5) years ranging from 18 to 47. Laser treatment was performed in 14 cases (2.7%). Retinal complications occurred in six cases (1.2%). The risk of retinal complication was significantly higher among patients with high axial length (OR = 1.3, 95% CI 1.2, 1.4) and patients with high pre-spherical equivalent before ICL (OR = 1.09, 95% CI 1.03, 1.4). CONCLUSION: Patients with higher axial length and higher pre-spherical equivalent before ICL implantation are at high risk of retinal complications.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Adulto Jovem , Adulto , Implante de Lente Intraocular/efeitos adversos , Acuidade Visual , Estudos Retrospectivos , Arábia Saudita/epidemiologia , Refração Ocular , Miopia/epidemiologia , Miopia/cirurgia , Miopia/etiologia , Lentes Intraoculares Fácicas/efeitos adversos , Hospitais , Seguimentos
6.
PLoS One ; 19(3): e0296811, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38512912

RESUMO

BACKGROUND: To analyze vault effects of crystalline lens rise (CLR) and anterior chamber parameters (recorded by Pentacam) in highly myopic patients receiving implantable collamer lenses (ICLs), which may avoid subsequent complications such as glaucoma and cataract caused by the abnormal vault. METHODS: We collected clinical data of 137 patients with highly myopic vision, who were all subsequent recipients of V4c ICLs between June 2020 and January 2021. Horizontal ciliary sulcus-to-sulcus diameter (hSTS) and CLR were measured by ultrasonic biomicroscopy (UBM), and a Pentacam anterior segment analyzer was used to measure horizontal white-to-white diameter (hWTW), anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), CLR, and postoperative vault (Year 1 and Month 1). The lens thickness (LT) was determined by optical biometry (IOL Master instrument). The predictive model was generated through multiple linear regression analyses of influential factors, such as hSTS, CLR, hWTW, ACD, ACA, ACV, ICL size, and LT. The predictive performance of the multivariate model on vault after ICL was assessed using the receiver operating characteristic (ROC) curve with area under the curve (AUC) as well as the point of tangency. RESULTS: Average CLR assessed by UBM was lower than the average value obtained by Pentacam (0.561 vs. 0.683). Bland-Altman analysis showed a good consistency in the two measurement methods and substantial correlation (r = 0.316; P = 0.000). The ROC curve of Model 1 (postoperative Year 1) displayed an AUC of 0.847 (95% confidence interval [CI]: 74.19-95.27), with optimal threshold of 0.581 (sensitivity, 0.857; specificity, 0.724). In addition, respective values for Model 2 (postoperative Month 1) were 0.783 (95% CI: 64.94-91.64) and 0.522 (sensitivity, 0.917; specificity, 0.605). CONCLUSION: CLR and anterior chamber parameters are important determinants of postoperative vault after ICL placement. The multivariate regression model we constructed may serve in large part as a predictive gauge, effectively avoid postoperative complication.


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/efeitos adversos , Acuidade Visual , Cristalino/cirurgia , Câmara Anterior/diagnóstico por imagem , Miopia/cirurgia , Estudos Retrospectivos
7.
Sci Rep ; 14(1): 5648, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38453996

RESUMO

Implantable collamer lens implantation (ICL) represents a safe and effective treatment for myopia and myopic astigmatism. To compare the outcomes of a bilateral one-stage same day approach to a two-stage approach, the databases of the University Eye Hospital Munich, Ludwig Maximilians-University and Smile Eyes Linz, Austria were screened for eyes that had undergone ICL implantation. Two-stage surgery was performed at an interval of 1 day (17 patients), 2 days (19 patients) and 1 week (2 patients). Variables analyzed were preoperative, 1-day and last follow-up uncorrected distance (UDVA) and corrected distance visual acuity (CDVA), manifest refraction, refractive spherical equivalent (SEQ), astigmatism, age, endothelial cell count (ECD), intraocular pressure (IOP) and ICL vaulting. In total, 178 eyes (100 eyes one-stage, 78 eyes two-stage) of 89 patients were included in this study. Mean follow-up was 1.1 ± 0.8 and 1.3 ± 0.5 years. Mean preoperative SEQ was - 7.9 ± 2.6 diopters (D) in the one-stage and - 8.0 ± 1.7 D in the two-stage group (p = 0.63) and improved to 0.00 ± 0.40 and - 0.20 ± 0.40 D at end of follow-up, showing slightly better stability in the one-stage group (p = 0.004). There was no difference in the efficacy (1.1 vs. 1.2, p = 0.06) and the safety index (1.2 vs. 1.2, p = 0.60) between the two groups. No eye (0%) in either group lost 2 lines or more of UDVA (p > 0.99). Refraction within ± 0.50 D and ± 1.00 D around target was achieved comparably often (89 vs. 86%, p = 0.65; 99 vs. 99%, p > 0.99). Endothelial cell loss was slightly higher in the two-stage group (1.3 vs. 4.3%). Vaulting at the final follow up was higher in the one-stage group (373.8 ± 205.4 µm vs. 260.3 ± 153.5 µm, p = 0.00007). There were no serious intraoperative complications in either group. In conclusion, this study demonstrates that both the one- and two-stage approaches are equally effective, predictable and safe. Regarding endothelial cell loss, vaulting and SEQ stability, the one-stage group showed slightly better outcomes, but these results are clinically questionable because they are so small. Larger studies are needed to quantitatively evaluate a potential benefit.


Assuntos
Astigmatismo , Lentes Intraoculares , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular , Acuidade Visual , Refração Ocular , Resultado do Tratamento , Astigmatismo/cirurgia , Seguimentos , Estudos Retrospectivos
8.
J Refract Surg ; 40(3): e126-e132, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466764

RESUMO

PURPOSE: To use artificial intelligence (AI) technology to accurately predict vault and Implantable Collamer Lens (ICL) size. METHODS: The methodology focused on enhancing predictive capabilities through the fusion of machine-learning algorithms. Specifically, AdaBoost, Random Forest, Decision Tree, Support Vector Regression, LightGBM, and XGBoost were integrated into a majority-vote model. The performance of each model was evaluated using appropriate metrics such as accuracy, precision, F1-score, and area under the curve (AUC). RESULTS: The majority-vote model exhibited the highest performance among the classification models, with an accuracy of 81.9% area under the curve (AUC) of 0.807. Notably, LightGBM (accuracy = 0.788, AUC = 0.803) and XGBoost (ACC = 0.790, AUC = 0.801) demonstrated competitive results. For the ICL size prediction, the Random Forest model achieved an impressive accuracy of 85.3% (AUC = 0.973), whereas XG-Boost (accuracy = 0.834, AUC = 0.961) and LightGBM (accuracy = 0.816, AUC = 0.961) maintained their compatibility. CONCLUSIONS: This study highlights the potential of diverse machine learning algorithms to enhance postoperative vault and ICL size prediction, ultimately contributing to the safety of ICL implantation procedures. Furthermore, the introduction of the novel majority-vote model demonstrates its capability to combine the advantages of multiple models, yielding superior accuracy. Importantly, this study will empower ophthalmologists to use a precise tool for vault prediction, facilitating informed ICL size selection in clinical practice. [J Refract Surg. 2024;40(3):e126-e132.].


Assuntos
Lentes Intraoculares , Lentes Intraoculares Fácicas , Humanos , Inteligência Artificial , Aprendizado de Máquina , Algoritmos , Área Sob a Curva , Estudos Retrospectivos
9.
J Refract Surg ; 40(3): e142-e147, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466767

RESUMO

PURPOSE: To evaluate the accuracy of the Reinstein formula with hand-held ultrasound biomicroscopy (UBM) measurements for sizing of the Implantable Collamer Lens (ICL). METHODS: A total of 107 myopic eyes of 57 patients implanted with the ICL were included in the study. The size of the ICL was selected based on the manufacturer's recommendations. Agreement between the vault predicted by the Reinstein formula and the vault measured postoperatively was analyzed with Bland-Altman plots. RESULTS: A total of 95% and 81% of patients had a postoperative vault ranging from 150 to 1,000 and 250 to 750 µm, respectively. The mean vault predicted by the Reinstein formula and the postoperative vault in the current study were 580 ± 181 and 547 ± 200 µm, respectively. The size recommendations of the Reinstein formula and the formula provided by the manufacturer, the Kojima formula, and the Dougherty formula overlapped in 50%, 57%, and 49% of eyes, respectively. CONCLUSIONS: The results show that the Reinstein formula combined with a hand-held UBM provides reliable sizing predictions of the ICL. However, considering that robotic UBM measurements have demonstrated a narrower range of deviation in predicting vault depth in previous studies, a direct comparison study between robotic UBM and hand-held UBM measurements is necessary to fully assess the limitations of combining hand-held UBM with the Reinstein formula. [J Refract Surg. 2024;40(3):e142-e147.].


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Microscopia Acústica/métodos , Implante de Lente Intraocular/métodos , Acuidade Visual , Miopia/cirurgia , Estudos Retrospectivos
10.
J Refract Surg ; 40(3): e182-e194, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466762

RESUMO

PURPOSE: To provide an up-to-date review of the agreement in automated white-to-white (WTW) measurement between the latest topographic and biometric devices. METHODS: In this systematic review, PubMed, Web of Science, and Scopus databases were searched for articles published between 2017 and 2023, focusing on WTW agreement studies on adult, virgin eyes, with or without cataract and no other ocular comorbidities. Studies evaluating WTW measurements performed with autokeratometers, manual calipers, or manual image analysis were excluded. When available, the following metrics for the agreement of WTW measurements between pairs of devices were included: mean difference ± standard deviation, 95% limits of agreement (LoA), LoA width, 95% confidence interval (95 CI%), and intraclass correlation coefficient (ICC). RESULTS: Forty-one studies, covering comparisons for 19 devices, were included. Altogether, 81 paired comparisons were performed for 4,595 eyes of 4,002 individuals. The mean difference in WTW measurements between devices ranged from 0.01 mm up to 0.96 mm, with varying CI. The 95% LoA width ranged from 0.31 to 2.45 mm (median: 0.65 mm). The majority of pairwise comparisons reported LoA wider than 0.5 mm, a clinically significant value for phakic intraocular lens sizing. CONCLUSIONS: Nearly all analyzed studies demonstrated the lack of interchangeability of the WTW parameter. The corneal diameter, assessed by means of grayscale en-face image analysis, tended to demonstrate the lowest agreement among devices compared to other measured biometric parameters. [J Refract Surg. 2024;40(3):e182-e194.].


Assuntos
Córnea , Lentes Intraoculares Fácicas , Adulto , Humanos , Topografia da Córnea/métodos , Câmara Anterior , Biometria/métodos , Reprodutibilidade dos Testes
11.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466765

RESUMO

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/métodos , Miopia/cirurgia , Acomodação Ocular , Câmara Anterior/diagnóstico por imagem , Pseudofacia/cirurgia , Tomografia de Coerência Óptica , Biometria
12.
Sci Rep ; 14(1): 3484, 2024 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-38346992

RESUMO

Sulcus-to-sulcus vertical diameter is longer than the horizontal. However, the effect of vertical positioning of the implantable collamer lens (ICL) on the vault compared to preoperative prediction is unclear. This prospective consecutive case series aimed to examine postoperative and preoperative predicted vaults during vertical ICL fixation. This study assessed 180 right eyes in 180 patients with myopic astigmatism. For the 90 eyes in 90 patients who underwent horizontal fixation (horizontal group) and 90 eyes in 90 patients who underwent vertical fixation (vertical group), biometrics by three-dimensional tomography of the anterior segment optical coherence tomography (A-OCT) was performed before surgery and 2 h, 1 day, 1 week, 1 month and 3 months after surgery. The anterior chamber depth did not change over time in both groups, and there was no significant difference from preoperative values. The postoperative vault values were significantly lower in the vertical group than in horizontal group over time. The difference between vault measurements and preoperative predictions at all postoperative time points was significantly greater in the vertical group than in horizontal group. Vertical fixation of the ICL reduced the vault by > 100 µm compared with horizontal fixation, which was different from the A-OCT preoperative predicted value.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Estudos Prospectivos , Miopia/cirurgia , Implante de Lente Intraocular/métodos , Olho , Estudos Retrospectivos
13.
BMC Ophthalmol ; 24(1): 70, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38360631

RESUMO

BACKGROUND: Studies on the factors affecting vault after posterior chamber phakic Implantable Collamer Lens (ICL) have been carried out, but most of them are single-centered and subjective selections of parameters. The present study aimed to systematically analyze the factors for vault. METHODS: A systematic review of case series, case-control, and cohort studies derived from the articles published in PubMed, the Cochrane Library, Embase, Web of Science, CNKI, CBM, Wanfang and VIP, as well as ClinicalTrials, which were conducted to search for studies on factors of vault using four core terms: phakic intraocular lenses, vault, risk factor and observational study, from January 01, 1997, to February 20, 2023. The included studies were meta-analyzed quantitatively and described qualitatively. Subsequently, meta-regression and subgroup analysis were used. RESULTS: We identified 13 studies (1,607 subjects), and 14 factors were considered. Meta-analysis showed that anterior chamber depth (ACD), horizontal corneal white-to-white (hWTW), ICL-size, and age are dual effects of the abnormal vaults; anterior chamber volume (ACV) and lens thickness (LT) are a one-way effect; while axial length (AL), ICL- spherical equivalent (ICL-SE) and Km are insignificant. In addition, descriptive analysis of anterior chamber angle (ACA), horizontal sulcus to sulcus (hSTS), ciliary processes height (T value), crystalline lens rise (CLR), and gender showed that all factors except gender tend to have significant effects on vault. Sensitivity analysis showed stable combined results. Country and design respectively affect the heterogeneity in ACD and ICL-size at low vault, while design affects the heterogeneity in ACD at high vault. No publication bias exists. CONCLUSIONS: Vault after ICL is related to multiple factors, especially anterior segmental biologic parameters, and they are weighted differently. We hope to provide a reference for the selection and adjustment of ICL.


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Miopia/cirurgia , Implante de Lente Intraocular/métodos , Refração Ocular , Estudos Retrospectivos , Estudos Observacionais como Assunto
14.
Int Ophthalmol ; 44(1): 94, 2024 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-38368308

RESUMO

PURPOSE: In the conventional technique, viscoelastic agents are typically rinsed away with balanced salt solution (BSS), but it may lead to a series of complications such as viscoelastic residue, anterior chamber instability and intraoperative TICL rotation. The utilization of irrigation and aspiration (I/A) has been shown to be effective in maintaining anterior chamber stability, reducing the incidence of postoperative high intraocular pressure, and minimizing postoperative fundus complications. However, there is a lack of previous studies investigating the impact of I/A on corneal endothelial cells during ICL implantation. The objective of this study was to examine the effect of I/A on corneal endothelial cells in patients undergoing myopia correction through implantation of Implantable Collamer Lens with a central hole (V4c ICL). METHODS: A retrospective selection was made of 344 eyes from 172 patients who underwent V4c ICL implantation and I/A to remove viscoelastic agent from the anterior chamber between 2021 and 2022. The intraocular pressure (IOP) was measured at 1 h, 2 h and 3 h after surgery. Corneal endothelial cell density (ECD), coefficient of variation in cell size (CV), standard deviation of cell area (SD), and percentage of hexagonal cells (HEX) were evaluated at 1 week postoperatively to assess corneal endothelial cells. The first two represent polymegethism or morphological variation, while the third parameter represents the degree of polymorphism of the corneal endothelial cells. Electronic medical records were utilized for data collection purpose. RESULTS: All surgeries proceeded without complications. The IOP was 16.50 ± 3.42 mmHg (range: 11.5-22.3 mmHg) prior to surgery and increased to 21.25 ± 5.61 mmHg (range: 9.5-34.8 mmHg), 19.85 ± 5.18 mmHg (range: 11.4-36.2 mmHg) and finally settled at an average of 18.81 ± 4.57 mmHg (range: 10.1-38.8 mmHg) at the respective time points of 1 h, 2 h and 3 h after surgery. The preoperative ECD was recorded as being approximately 3004 ± 295 cell/mm2, which exhibited a marginal decreased of 1.17% postoperatively, resulting in an average ECD value of 2969 ± 303 cell/mm2 one week after surgery (P = 0.12). Similarly, the preoperative CV was determined as 31.10 ± 3.78%, and it experienced a slight reduction with an average CV value of 30.74 ± 3.77% at week after surgery (P = 0.21). And, the preoperative SD was reported as 104.76 ± 17.26, and it remained virtually unchanged with an average SD value of 104.85 ± 18.75 at one week after surgery (P = 0.95). The preoperative HEX was calculated as 55.38 ± 8.94%, and it remained its stability with an average HEX value of 55.45 ± 8.73% one week after surgery (P = 0.92). CONCLUSION: The utilization of I/A led to a slight decrease in postoperative ECD when compared to conventional surgical techniques. Nevertheless, the reduction in ECD remained within acceptable limits, taking into accout the avervantaged it offered, such as stabilization of the anterior chamber and decreased occurrence of viscoelastic residue after surgery. It is challenging to anticipate the long-term safety of corneal endothelial cells based on current short-term studies. However, this study provides a valuable reference indicating that neither anterior chamber irrigation nor I/A aspiration have an adverse impact on the safety of corneal endothelial cells in the short term. Further research is imperative to enhance our understanding of their effects over an extended period.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Refração Ocular , Acuidade Visual , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Células Endoteliais , Miopia/cirurgia
15.
Am J Ophthalmol ; 261: 7-18, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38218514

RESUMO

BACKGROUND: Achieving precise refractive outcomes in phakic posterior chamber intraocular lens (pIOL) implantation is crucial for patient satisfaction. This study investigates factors affecting pIOL power calculations, focusing on myopic eyes, and evaluates the potential benefits of advanced predictive models. DESIGN: Retrospective, single-center, algorithm improvement study. METHODS: Various variations with different effective lens position (ELP) algorithms were analyzed. The algorithms included a fixed constant model, and a multiple linear regression model and were tested with and without incorporation of the posterior corneal curvature (Rcp). Furthermore, the impact of inserting the postoperative vault, the space between the pIOL and the crystalline lens, into the ELP algorithm was examined, and a simple vault prediction model was assessed. RESULTS: Integrating Rcp and the measured vault into pIOL calculations did not significantly improve accuracy. Transitioning from constant model approaches to ELP concepts based on linear regression models significantly improved pIOL power calculations. Linear regression models outperformed constant models, enhancing refractive outcomes for both ICL and IPCL pIOL platforms. CONCLUSIONS: This study underscores the utility of implementing ELP concepts based on linear regression models into pIOL power calculation. Linear regression based ELP models offered substantial advantages for achieving desired refractive outcomes, especially in lower to medium power pIOL models. For pIOL power calculations in both pIOL platforms we tested with preoperative measurements from a Scheimpflug device, we found improved results with the LION 1ICL formula and LION 1IPCL formula. Further research is needed to explore the applicability of these findings to a broader range of pIOL designs and measurement devices.


Assuntos
Cristalino , Lentes Intraoculares Fácicas , Humanos , Estudos Retrospectivos , Implante de Lente Intraocular/métodos , Córnea
16.
Zhonghua Yan Ke Za Zhi ; 60(2): 168-175, 2024 Feb 11.
Artigo em Chinês | MEDLINE | ID: mdl-38296322

RESUMO

Objective: To analyze the early changes in vault height and its influencing factors after implantation of posterior chamber phakic intraocular lenses (pIOL). Methods: A retrospective case series study was conducted, including patients who underwent pIOL implantation at Zhongshan Ophthalmic Center, Sun Yat-sen University, from September 2020 to August 2021, and completed a 3-month follow-up. Data were collected from myopic or myopic astigmatism patients. Preoperative ocular examinations, including Pentacam anterior segment analysis system, Sirius anterior segment analysis system, ultrasound biomicroscopy (UBM), and IOLMaster optical biometry, were performed to measure parameters such as refractive power, corneal curvature, corneal horizontal diameter, anterior chamber volume, anterior chamber depth, pupil diameter, sulcus-to-sulcus diameter (STS), and lens thickness. The degree and position of implanted pIOL, as well as vault height measured by anterior segment optical coherence tomography (AS-OCT) at 1 day, 1 week, 1 month, and 3 months postoperatively, were recorded. Statistical analyses were conducted using repeated measures analysis of variance, Pearson correlation analysis, and multiple linear regression analysis. Results: A total of 314 patients (314 eyes) were included, with 52 male (16.56%) and 262 female (83.44%) patients, and an average age of (26.44±4.60) years. The preoperative equivalent spherical power was (-8.09±2.41) D. Postoperative vault heights at 1 day, 1 week, 1 month, and 3 months were (671.88±273.02) µm, (652.26±272.21) µm, (615.08±259.69) µm, and (591.14±250.71) µm, respectively, with statistically significant differences among groups (P<0.001). Eyes with vault height>750 µm showed a greater decrease in early postoperative vault height (P<0.001). The eyes implanted with 12.1 mm pIOL had the lowest postoperative vault height, while those with 13.2 mm had the highest (P>0.05). Factors correlated with vault height at 1 day postoperatively included corneal horizontal diameter, anterior chamber depth, preoperative cylinder power, angle degree, lens thickness, and pIOL cylinder power. Factors correlated with vault height at 3 months postoperatively included corneal horizontal diameter, anterior chamber depth, preoperative cylinder power, anterior chamber volume, angle degree, lens thickness, axial length, pIOL spherical and cylinder power. Factors associated with changes in early postoperative vault height included corneal curvature K2, anterior chamber depth, anterior chamber volume, pupil diameter, horizontal STS, vertical STS, axial length, and preoperative spherical power (all P<0.05). Multiple linear regression analysis revealed that lens thickness significantly influenced vault height at 1 day postoperatively, anterior chamber volume significantly influenced vault height at 3 months postoperatively, and pupil diameter significantly influenced changes in early postoperative vault height (all P<0.05). Conclusions: Vault height after pIOL implantation is unstable in the early postoperative period and gradually decreases within 3 months. A higher baseline vault height is associated with a greater decrease. Anterior chamber volume, pupil diameter, and lens thickness are influencing factors on vault height during the first 3 months postoperatively.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Câmara Anterior , Miopia/cirurgia
17.
J Cataract Refract Surg ; 50(4): 420-423, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38194352

RESUMO

Endothelial cell density (ECD) loss is a noted effect of implantable collamer lens (ICL) V4c surgery. Current literature provides a wide range of values for ECD loss postsurgery, which may not be helpful in advising patients and clinicians. A meta-analysis exploring ECD loss in ICL V4c for myopia correction was undertaken. 18 studies were included in this meta-analysis with 2 subgroup analyses to account for the variability in follow-up lengths. The average ECD loss 3 months, 12 months, and 21.25 (mean) months postsurgery were 1.32% ± 1.28% ( P < .001, 95% CI, -75.158 to -1.19), 1.75% ± 2.17% ( P < .001, 95% CI, -134.09 to 14.52), and 3.84% ± 1.78% ( P < .001, 95% CI, -156.04 to -54.26), respectively. ECD loss is most pronounced 3 months postsurgery, suggesting that acute surgical trauma was the primary contributor rather than long-term lens implantation. Overall, ICL V4c is for myopia correction exhibits similar ECD loss as seen in other ICL models, thereby affirming its safety.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Acuidade Visual , Implante de Lente Intraocular , Miopia/cirurgia
18.
Curr Opin Ophthalmol ; 35(2): 138-146, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38059758

RESUMO

PURPOSE OF REVIEW: Posterior chamber phakic intraocular lenses (pIOLs) are increasing in popularity as a viable alternative to laser refractive surgery. The purpose of this review is to evaluate the recent updates to pIOLs and to assess the advancements and safety of the procedure. RECENT FINDINGS: Accurate lens sizing is the key determinant to suitable vault prediction, advancements to sizing formulae including the use of very high frequency (VHF) digital ultrasound and the application of artificial intelligence and machine learning has led to improved vault prediction and safety. The introduction of the central aquaport has been shown to reduce the formation of cataract and is now adopted in most myopic pIOLs. Recently published studies have demonstrated that pIOLs have an excellent safety profile with no increased risk of retinal detachment or endothelial cell loss. Advancements have led to the introduction of extended depth of focus pIOLs for the correction of presbyopia, further research is required to evaluate the efficacy of new lens designs. SUMMARY: pIOL surgery is experiencing traction with improved lens design and increased lenses choices such as larger optical zone and presbyopic options. Accuracy of implantable collamer lens sizing is paramount to the safety and clinical outcomes, greater predictability is likely to encourage more posterior chamber pIOL users due to fewer sizing related complications.


Assuntos
Cristalino , Lentes Intraoculares , Miopia , Lentes Intraoculares Fácicas , Humanos , Lentes Intraoculares Fácicas/efeitos adversos , Inteligência Artificial , Implante de Lente Intraocular/efeitos adversos , Miopia/cirurgia
19.
Am J Ophthalmol ; 259: 88-95, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37952651

RESUMO

PURPOSE: This study aimed to analyze the relationship between visual quality and implantable collamer lenses (ICL) decentration. DESIGN: Prospective treatment evaluation clinical study METHODS: This prospective study included 119 eyes with ICL implantation. Refractive parameters and ocular aberrations were examined pre- and postoperatively. ICL decentration and higher-order aberrations (HOAs) were evaluated using the OPD-Scan III aberrometer. RESULTS: At the 1-month follow-up, the mean values for decentration were 0.38 ± 0.19 mm (0.02-0.78). Regarding the position of decentration in right and left eyes, 22.8% and 17.7% were located in the superior nasal section, 0% and 6.5% in the inferior nasal section, 50.9% and 53.2% in the superior temporal section, and 26.3% and 22.6% in the inferior temporal section, respectively. The root mean square values of whole-eye total HOAs, coma, and trefoil had significantly increased. Decentration had a significant negative correlation with variation in the pre- and postoperative trefoils of the whole eye. CONCLUSIONS: ICL decentration had a slightly negative correlation with trefoil and slightly affected visual quality.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Fácicas , Humanos , Acuidade Visual , Implante de Lente Intraocular , Estudos Prospectivos , Refração Ocular
20.
J Cataract Refract Surg ; 50(3): 276-282, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38031330

RESUMO

PURPOSE: To examine the risk factors for haptic malposition in eyes with implantable collamer lens (ICL). SETTING: Eye and ENT Hospital, Fudan University, Shanghai, China. DESIGN: Prospective nonrandomized observational study. METHODS: This study included 134 (77.9%) of 172 initially enrolled patients who underwent ICL implantation and completed a 1-year follow-up. The extent of haptics present in the ciliary sulcus (ICS) was measured. Patients were categorized based on ICS count (0 to 4). The position of the haptics was quantified as the distance between the iris root and the terminal tip of ICL haptics (iris root to haptic tip, IRH). The related factors to the ICS count and its correlation with the central vault were analyzed. RESULTS: ICS distribution was 0 ICS in 19 eyes (14.2%), 1 in 22 eyes (16.4%), 2 in 32 eyes (23.9%), 3 in 29 eyes (21.6%), and 4 in 32 eyes (23.9%). Parameters like maximum ciliary body thickness (CBTmax, P = .008), iris-ciliary process distance (ICPD, P < .001), and ciliary process length ( P = .034) varied significantly across ICS groups. A multiple linear regression analysis revealed that the iris-ciliary angle ( P = .006), CBTmax ( P = .007), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL, P = .035), and ICL size ( P = .015) were significantly associated with IRH. Spherical equivalents ( P = .042), STSL ( P = .001), and ICS count ( P = .020) significantly correlated with the central vault. CONCLUSIONS: Shortened ciliary process is a primary risk for haptic malposition. The ICS count significantly relates to the central vault.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Tecnologia Háptica , Estudos Prospectivos , Implante de Lente Intraocular , Acuidade Visual , Miopia/cirurgia , China , Iris , Fatores de Risco , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...